ZULU Modem
Register Setting (Configuration Mode)
The internal registers enable various parameters to be controlled.
To set a register type ‘R#=x’ where # is the register number (1-6) and x is the value to set
For example to set the channel to channel 3 you would type the following.
R3=3<CR> (Where <CR> is carriage return or enter on the keyboard)
The modem will then return ‘OK’ or ‘Error’ if an incorrect command is entered.
One you have set the register values you must save the changes by typing S<CR>
The modem will return with ‘SAVED’
Value Range
Example
Register
R1
Description
0000 - FFFF
(24 bit address)
R1=0001
(Data sent is addressed to Zulu
MODEM with address 0001)
sets the recipient Zulu
MODEM Address
R2=F001
(Data sent is from Zulu MODEM
with address F001)
0000 - FFFF
(24 bit address)
Set own Zulu Modem ad-
dress
R2
R3
R3=2
Ch 1-8
Set RF channel
(Transmit on Channel 2)
0 = -8dBm
1 = -5dBm
2 = -2dBm
3 = +1dBm
4 = +4dBm
5 = +7dBm
6 = +10dBm
7 = +13dBm
Set the RF Transmit
Power output
R4=7
R4
(sets Transmit Power to max)*
0 = 9,600
1 = 19,200
2 = 28,800
3 = 56,000
R5=3
(sets the RF data rate to 56Kbps)
R5
set the RF baud rate
Tip!: The lower the RD Data Rate
the longer the achievable range!
*Note : reducing Tx power reduces battery consumption!
DS-ZULU Modem-1