PROTEXT - GSM R
EMOTE
C
ONTROL
Command
Description
The User Password can be an alphanumeric string
containing from 5 to10 characters.
Unit Password
(UPW)
Selection of the UPW must be completed within 5
minutes from power applied. Setting the UPW is
carried out by sending a text message to the unit.
If for any reason the unit password is lost the user
must remove all power to the unit for 1 minute, Then
start the process of entering a UPW again.
The <UNIT ID> is an alphanumeric string consisting
4 to 10 characters.
This sets the ‘identity’ of the PROTEXT unit, and is
included in any response to from PRIOTEXT so that
the user can identify the PROTEXT.
Command:
Password123456~UID~Identity7
Response:
Identity7~UID~OK
Command:
Password123456~INUM1~003361234567
8
Response:
Identity7~INUM1~0033612345678~OK
This example selects a French mobile
(country code 33) with national number 06
12 34 56 78 (leading 0 omitted), this
number will be text if IN1 changes state.
UPW~<UNIT PW>
Response:
UPW~OK
Command Syntax
Example
Command:
UPW~Password123456
Unit Identity
(UID)
<UNIT PW>~UID~<UNIT
ID>
(Optional)
number-to-
Input number-to-
text
(INUM)
This command sets the mobile number that the SMS
Text message is sent to when input is changed.
The number must be in full international format
including country code and leading zeros.
Note the country code for the United Kingdom is 44.
Note the PROTEXT can store up to 5 mobile
numbers per input.
<UNIT PW>~INUMn~<num
to text>
n=1
n=2
n=3
n=4
for
for
for
for
input1
input 2
input 3
input 4
(Optional)