RFHA1020
Specification
Typ.
Parameter
Unit
Condition
Min.
Max.
[1], [2]
RF Functional Test
(continued)
Small Signal Gain
15
dB
dB
f = 1300MHz, P = 30dBm
IN
Power Gain
12.3
f = 1300MHz, P = 41.7dBm
IN
Input Return Loss
Output Power
-10
-6
dB
f = 1300MHz, P = 41.7dBm
IN
54
48
dBm
%
f = 1300MHz, P = 41.7dBm
IN
Drain Efficiency
Small Signal Gain
Power Gain
55
14
f = 1300MHz, P = 41.7dBm
IN
dB
f = 1400MHz, P = 30dBm
IN
12.3
dB
f = 1400MHz, P = 41.7dBm
IN
Input Return Loss
Output Power
-8
-5.5
dB
f = 1400MHz, P = 41.7dBm
IN
54
48
dBm
%
f = 1400MHz, P = 41.7dBm
IN
Drain Efficiency
55
f = 1400MHz, P = 41.7dBm
IN
[1], [2]
RF Typical Performance
Frequency Range
1200
1400
MHz
dB
Small Signal Gain
15
13
P
P
= 30dBm
IN
Power Gain
dB
= 54.50dBm
OUT
Gain Variation with Temperature
-0.015
dB/°C
dBm
W
At peak output power
Peak output power
Peak output power
At peak output power
Output Power (P
)
54.50
280
55
SAT
Drain Efficiency
%
[1] Test Conditions: PW = 100s, DC = 10%, V
= 50V, I = 440mA, T = 25°C.
DQ
DSQ
[2] Performance in a standard tuned test fixture.
7628 Thorndike Road, Greensboro, NC 27409-9421 · For sales or technical
support, contact RFMD at (+1) 336-678-5570 or customerservice@rfmd.com.
DS120508