欢迎访问ic37.com |
会员登录 免费注册
发布采购

SF1131B 参数 Datasheet PDF下载

SF1131B图片预览
型号: SF1131B
PDF下载: 下载PDF文件 查看货源
内容描述: 266 MHz的SAW滤波器 [266 MHz SAW Filter]
分类和应用:
文件页数/大小: 3 页 / 109 K
品牌: RFM [ RF MONOLITHICS, INC ]
 浏览型号SF1131B的Datasheet PDF文件第2页浏览型号SF1131B的Datasheet PDF文件第3页  
SF1131B
Designed for GPS Applications
Quartz Temperature Stability
Small Size
Hermetic 7 x 5 mm Surface-mount Case
Complies with Directive 2002/95/EC (RoHS)
Pb
Value
+10
30
-40 to +85
260°C for 30 s
266 MHz
SAW Filter
Units
dBm
VDC
°C
Absolute Maximum Ratings
Rating
Maximum Incident Power in Passband
Max. DC voltage between any 2 terminals
Storage Temperature Range
Suitable for lead-free soldering - Max. Soldering Profile
SMP-03
Electrical Characteristics
Characteristic
Nominal Center Frequency
Passband
Insertion Loss at fc
1 db Passband
3 db Passband
Amplitude Ripple over fc±0.5 MHz
Group Delay Variation over fc ±1.1 MHz
Rejection
Operating Temperature Range
fc±10 MHz
T
A
GDV
1, 2, 3
1
50
-30
+85
Sym
f
C
IL
BW
1
BW
3
1, 2
0.5
2.2
2.6
1.0
250
Notes
1
Min
Typ
266.01
Max
12.0
Units
MHz
dB
MHz
dB
P-P
ns
P-P
dB
°C
Impedance Matching to 50Ω
Case Style
Lid Symbolization (YY = year, WW = week)
6
External L-C match required to 50 ohms
SMP-03 7 x 5 mm Nominal Footprint
RFM SF1131B YYWW
CAUTION: Electrostatic Sensitive Device. Observe precautions for handling.
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
Unless noted otherwise, all specifications apply over the operating temperature range with filter
soldered to the specified demonstration board with impedance matching to 50
Ω
and measured
with 50
Ω
network analyzer.
Unless noted otherwise, all frequency specifications are referenced to the nominal center
frequency, fc.
Rejection is measured as attenuation below the minimum IL point in the passband. Rejection in
final user application is dependent on PCB layout and external impedance matching design.
See Application Note No. 42 for details.
"LRIP" or "L" after the part number indicates "low rate initial production" and "ENG" or "E"
indicates "engineering prototypes."
The design, manufacturing process, and specifications of this filter are subject to change.
Tape and Reel Standard ANSI / EIA 481.
Either Port 1 or Port 2 may be used for either input or output in the design. However,
impedances and impedance matching may vary between Port 1 and Port 2, so that the filter
must always be installed in one direction per the circuit design.
US and international patents may apply.
Electrical Connections
Connection
Port 1
Port 2
Case Ground
Terminals
1, 10
5, 6
All others
www.RFM.com
E-mail: info@rfm.com
©2008 by RF Monolithics, Inc.
Page 1 of 3
SF1131B - 3/28/08