M61303FP
VthCP Clamp Pulse Threshold Voltage
Reduce the SG4 input level gradually from 5.0 VP-P, monitoring the waveform output. Measure the top level of input
pulse when the output pedestal voltage turn decrease with unstable.
WCP Clamp Pulse Minimum Width
Decrease the SG4 pulse width gradually from 0.5 μs, monitoring the output. Measure the SG4 pulse width (a point of
1.5 V) when the output pedestal voltage turn decrease with unstable.
OTr OSD Pulse Characteristics Tr
Measure the time needed for the output pulse to rise from 10% to 90% (OTr) with an active probe.
OTf OSD Pulse Characteristics Tf
Measure the time needed for the output pulse to fall from 90% to 10% (OTf) with an active probe.
Oaj1 OSD Adjust Control Characteristics1
Measure the amplitude output at OUT (2, 5, 9). The measured value is called VOUT (2, 5, 9), and is treated as Oaj1.
Oaj2 OSD Adjust Control Characteristics2
Measuring condition and procedure are the same as described in Oaj1.
ΔOaj2 OSD Adjust Control Relative Characteristics2
Relative characteristics ΔOaj2 is calculated by the equation below:
ΔOaj2 = VOUT (2) / VOUT (5),
VOUT (5) / VOUT (9),
VOUT (9) / VOUT (2)
Oaj3 OSD Adjust Control Characteristics3
Measuring condition and procedure are the same as described in Oaj1.
ΔOaj3 OSD Adjust Control Relative Characteristics3
Measuring condition and procedure are the same as described in ΔOaj2.
Oaj4 OSD Adjust Control Characteristics4
Measuring condition and procedure are the same as described in Oaj1.
Oaj5 OSD Adjust Control Characteristics5
Measuring condition and procedure are the same as described in Oaj1.
ΔOaj5 OSD Adjust Control Relative Characteristics5
Measuring condition and procedure are the same as described in ΔOaj2.
Oaj6 OSD Adjust Control Characteristics6
Measuring condition and procedure are the same as described in Oaj1.
ΔOaj6 OSD Adjust Control Relative Characteristics6
Measuring condition and procedure are the same as described ΔOaj2.