M61303FP  
INCT1 Crosstalk1 Input1-2 50 MHz-1  
Input SG3 (50 MHz) to pin 42 only, set Input SW of I2C BUS to 0 and then measure the waveform amplitude output at  
OUT (2). The measured value is called VOUT (2). On equal terms set Input SW of I2C BUS to 1. And then measure  
the waveform amplitude output at OUT (2)'. Crosstalk INCT1 is calculated by the equation below:  
VOUT (2)'  
INCT1 = 20log  
(dB)  
VOUT (2)  
Similarly measure the waveform amplitude output at OUT (5) when signal input only pin 37 and OUT when signal  
input only pin 32 and calculate crosstalk.  
INCT1' Crosstalk1' Input1-2 50 MHz-1  
Measuring condition and procedure are the same as described in INCT1, expect SG3 to 180 MHz.  
INCT2 Crosstalk2 Input1-2 50 MHz-1  
Input SG3 (50 MHz) to pin 40 only, set Input SW of I2C BUS to 1 and then measure the waveform amplitude output at  
OUT (2). The measured value is called VOUT (2). On equal terms set Input SW of I2C BUS to 0. And then measure  
the waveform amplitude output at OUT (2)'. Crosstalk INCT2 is calculated by the equation below:  
VOUT (2)'  
INCT2 = 20log  
(dB)  
VOUT (2)  
Similarly measure the waveform amplitude output at OUT (5) when signal input only pin 35 and OUT when signal  
input only pin 30 and calculate crosstalk.  
INCT2' Crosstalk2' Input1-2 50 MHz-1  
Measuring condition and procedure are the same as described in INCT2, expect SG3 to 180 MHz.  
CHCT1 Crosstalk1 between RGB Ch 50 MHz-1  
Input SG3 (50 MHz) to pin 42 only, and then measure the waveform amplitude output at OUT (2, 5, 9). The measured  
value is called VOUT (2, 5, 9). Crosstalk CHCT1 is calculated by the equation below:  
VOUT (5, 9)  
CHCT1 = 20log  
(dB)  
VOUT (2)  
CHCT1' Crosstalk1' between RGB Ch 180 MHz-1  
Measuring condition and procedure are the same as described in CHCT1, expect SG3 to 180 MHz.  
CHCT2 Crosstalk2 between RGB Ch 50 MHz-2  
Input SG3 (50 MHz) to pin 37 only, and then measure the waveform amplitude output at OUT (2, 5, 9). The measured  
value is called VOUT (2, 5, 9). Crosstalk CHCT2 is calculated by the equation below:  
VOUT (2, 9)  
CHCT2 = 20log  
(dB)  
VOUT (5)  
CHCT2' Crosstalk2' between RGB Ch 180 MHz-2  
Measuring condition and procedure are the same as described in CHCT2, expect SG3 to 180 MHz.  
CHCT3 Crosstalk3 between RGB Ch 50 MHz-3  
Input SG3 (50 MHz) to pin 32 only, and then measure the waveform amplitude output at OUT (2, 5, 9). The measured  
value is called VOUT (2, 5, 9). Crosstalk CHCT3 is calculated by the equation below:  
VOUT (2, 5)  
CHCT3 = 20log  
(dB)  
VOUT (9)  
CHCT3' Crosstalk3' between RGB Ch 50 MHz-3  
Measuring condition and procedure are the same as described in CHCT3, expect SG3 to 180 MHz.  