欢迎访问ic37.com |
会员登录 免费注册
发布采购

M61303FP 参数 Datasheet PDF下载

M61303FP图片预览
型号: M61303FP
PDF下载: 下载PDF文件 查看货源
内容描述: I2C总线控制3通道视频前置放大器, LCD显示屏 [I2C BUS Controlled 3channel Video Pre-amplifier for LCD Display Monitor]
分类和应用: 放大器
文件页数/大小: 25 页 / 233 K
品牌: RENESAS [ RENESAS TECHNOLOGY CORP ]
 浏览型号M61303FP的Datasheet PDF文件第8页浏览型号M61303FP的Datasheet PDF文件第9页浏览型号M61303FP的Datasheet PDF文件第10页浏览型号M61303FP的Datasheet PDF文件第11页浏览型号M61303FP的Datasheet PDF文件第13页浏览型号M61303FP的Datasheet PDF文件第14页浏览型号M61303FP的Datasheet PDF文件第15页浏览型号M61303FP的Datasheet PDF文件第16页  
M61303FP
INCT1 Crosstalk1 Input1-2 50 MHz-1
Input SG3 (50 MHz) to pin 42 only, set Input SW of I
2
C BUS to 0 and then measure the waveform amplitude output at
OUT (2). The measured value is called VOUT (2). On equal terms set Input SW of I
2
C BUS to 1. And then measure
the waveform amplitude output at OUT (2)'. Crosstalk INCT1 is calculated by the equation below:
INCT1 = 20log
VOUT (2)'
VOUT (2)
(dB)
Similarly measure the waveform amplitude output at OUT (5) when signal input only pin 37 and OUT when signal
input only pin 32 and calculate crosstalk.
INCT1' Crosstalk1' Input1-2 50 MHz-1
Measuring condition and procedure are the same as described in INCT1, expect SG3 to 180 MHz.
INCT2 Crosstalk2 Input1-2 50 MHz-1
Input SG3 (50 MHz) to pin 40 only, set Input SW of I
2
C BUS to 1 and then measure the waveform amplitude output at
OUT (2). The measured value is called VOUT (2). On equal terms set Input SW of I
2
C BUS to 0. And then measure
the waveform amplitude output at OUT (2)'. Crosstalk INCT2 is calculated by the equation below:
INCT2 = 20log
VOUT (2)'
VOUT (2)
(dB)
Similarly measure the waveform amplitude output at OUT (5) when signal input only pin 35 and OUT when signal
input only pin 30 and calculate crosstalk.
INCT2' Crosstalk2' Input1-2 50 MHz-1
Measuring condition and procedure are the same as described in INCT2, expect SG3 to 180 MHz.
CHCT1 Crosstalk1 between RGB Ch 50 MHz-1
Input SG3 (50 MHz) to pin 42 only, and then measure the waveform amplitude output at OUT (2, 5, 9). The measured
value is called VOUT (2, 5, 9). Crosstalk CHCT1 is calculated by the equation below:
CHCT1 = 20log
VOUT (5, 9)
VOUT (2)
(dB)
CHCT1' Crosstalk1' between RGB Ch 180 MHz-1
Measuring condition and procedure are the same as described in CHCT1, expect SG3 to 180 MHz.
CHCT2 Crosstalk2 between RGB Ch 50 MHz-2
Input SG3 (50 MHz) to pin 37 only, and then measure the waveform amplitude output at OUT (2, 5, 9). The measured
value is called VOUT (2, 5, 9). Crosstalk CHCT2 is calculated by the equation below:
CHCT2 = 20log
VOUT (2, 9)
VOUT (5)
(dB)
CHCT2' Crosstalk2' between RGB Ch 180 MHz-2
Measuring condition and procedure are the same as described in CHCT2, expect SG3 to 180 MHz.
CHCT3 Crosstalk3 between RGB Ch 50 MHz-3
Input SG3 (50 MHz) to pin 32 only, and then measure the waveform amplitude output at OUT (2, 5, 9). The measured
value is called VOUT (2, 5, 9). Crosstalk CHCT3 is calculated by the equation below:
CHCT3 = 20log
VOUT (2, 5)
VOUT (9)
(dB)
CHCT3' Crosstalk3' between RGB Ch 50 MHz-3
Measuring condition and procedure are the same as described in CHCT3, expect SG3 to 180 MHz.
Rev.2.00 Sep 14, 2006 page 12 of 24