M52742ASP
V
SC1
Sub Contrast Control Characteristics1
Measure the amplitude output at OUT (29, 32, 35). The measured value is called VOUT (29, 32, 35). Sub contrast
control characteristics V
SC1
is calculated by the equation below:
V
SC1
= 20log
VOUT
(dB)
0.7
∆V
SC1
Sub Contrast Control Relative Characteristics1
Relative characteristics
∆V
SC1
is calculated by the equation below:
∆V
SC1
= VOUT (29) / VOUT (32),
VOUT (32) / VOUT (35),
VOUT (35) / VOUT (29).
V
SC2
Sub Contrast Control Characteristics2
Measuring condition and procedure are the same as described in V
SC1
.
∆V
SC2
Sub Contrast Control Relative Characteristics2
Measuring condition and procedure are the same as described in
∆V
SC1
.
V
SC3
Sub Contrast Control Characteristics3
Measuring the amplitude output at OUT (29, 32, 35).
The measured value is called VSC3
∆V
SC3
Sub Contrast Control Relative Characteristics3
Measuring condition and procedure are the same as described in
∆V
SC1
.
VMSC Main/sub Contrast Control Characteristics
Measure the amplitude output at OUT (29, 32, 35). The measured value is called VMSC.
∆VMSC
Main/sub Contrast Control Relative Characteristics
Relative characteristics
∆VMSC
is calculated by the equation below:
∆VMSC
= VOUT (29) / VOUT (32),
VOUT (32) / VOUT (35),
VOUT (35) / VOUT (29)
ABL1 ABL Control Characteristics1
Measure the amplitude output at OUT (29, 32, 35). The measured value is called VOUT (29, 32, 35), and is treated as
ABL1.
∆ABL1
ABL Control Relative Characteristics1
Relative characteristics
∆ABL1
is calculated by the equation below:
∆ABL1
= VOUT (29) / VOUT (32) ,
VOUT (32) / VOUT (35) ,
VOUT (35) / VOUT (29)
REJ03F0192-0201 Rev.2.01 Mar 31, 2008
Page 9 of 26