M52742ASP
G
V
Maximum Gain
Input SG1, and read the amplitude output at OUT (29, 32, 35). The amplitude is called VOUT (29, 32, 35). Maximum
gain G
V
is calculated by the equation below:
G
V
= 20log
VOUT
(dB)
0.7
∆G
V
Relative Maximum Gain
Relative maximum gain
∆G
V
is calculated by the equation below:
∆G
V
= VOUT (29) / VOUT (32),
VOUT (32) / VOUT (35),
VOUT (35) / VOUT (29)
V
C1
Main Contrast Control Characteristics1
Measuring the amplitude output at OUT (29, 32, 35). The measured value is called VOUT (29, 32, 35). Main contrast
control characteristics V
C1
is calculated by the equation below:
V
C1
= 20log
VOUT
(dB)
0.7
∆V
C1
Main Contrast Control Relative Characteristics1
Relative characteristics
∆V
C1
is calculated by the equation below:
∆V
C1
= VOUT (29) / VOUT (32),
VOUT (32) / VOUT (35),
VOUT (35) / VOUT (29)
V
C2
Main Contrast Control Characteristics2
Measuring condition and procedure are the same as described in V
C1
.
∆V
C2
Main Contrast Control Relative Characteristics2
Measuring condition and procedure are the same as described in
∆V
C1
.
V
C3
Main Contrast Control Characteristics3
Measuring the amplitude output at OUT (29, 32, 35).
The measured value is called VOUT (29, 32, 35).
∆V
C3
Main Contrast Control Relative Characteristics3
Measuring condition and procedure are the same as described in
∆V
C1
.
REJ03F0192-0201 Rev.2.01 Mar 31, 2008