MULTIJUNCTION TIMERS
10.4 TIO (Input/Output-Related 16-Bit Timer)
10
TIO7 Control Register (TIO7CR)
<Address: H’0080 036B>
b8
9
10
0
11
12
0
13
0
14
TIO7M
0
b15
0
TIO7CKS
TIO7ENS
0
0
0
<After reset: H’00>
b
8
Bit Name
Function
R
0
W
0
No function assigned. Fix to "0".
9, 10
TIO7CKS
00: Clock bus 0
01: Clock bus 1
10: Clock bus 2
11: Clock bus 3
R
W
TIO7 clock source select bit
11, 12
13–15
TIO7ENS
00: No selection
R
R
W
W
TIO7 enable/measure input source select bit
01: External input TIN9
10: Input event bus 0
11: Input event bus 3
TIO7M
000: Single-shot output mode
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
TIO7 operation mode select bit
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: – ditto –
Note: • Operation mode can only be set or changed while the counter is inactive.
TIO8 Control Register (TIO8CR)
<Address: H’0080 038A>
b0
1
0
2
0
3
TIO8ENS
0
4
0
5
0
6
TIO8M
0
b7
0
TIO8CKS
0
<After reset: H’00>
b
Bit Name
TIO8CKS
Function
R
R
W
W
0, 1
100: Clock bus 0
101: Clock bus 1
110: Clock bus 2
111: Clock bus 3
TIO8 clock source select bit
2–4
TIO8ENS
000: No selection
001: – ditto –
R
W
TIO8 enable/measure input source select bit
010: – ditto –
011: – ditto –
100: External input TIN10
101: Input event bus 1
110: Input event bus 2
111: Input event bus 3
5–7
TIO8M
000: Single-shot output mode
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
R
W
TIO8 operation mode select bit
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: – ditto –
Note: • Operation mode can only be set or changed while the counter is inactive.
32180 Group User’s Manual (Rev.1.0)
10-108