MULTIJUNCTION TIMERS
10.4 TIO (Input/Output-Related 16-Bit Timer)
10
TIO6 Control Register (TIO6CR)
<Address: H’0080 036A>
D0
1
TIO6CKS
0
2
0
3
4
0
5
0
6
TIO6M
0
D7
0
TIO6ENS
0
0
<After reset: H’00>
b
Bit Name
TIO6CKS
Function
R
R
W
W
0–2
000: External input TCLK2
001: – ditto –
TIO6 clock source select bit
010: – ditto –
011: – ditto –
100: Clock bus 0
101: Clock bus 1
110: Clock bus 2
111: Clock bus 3
3, 4
5–7
TIO6ENS
00: No selection
R
R
W
W
TIO6 enable/measure input source select bit
01: External input TIN8
10: Input event bus 2
11: Input event bus 3
TIO6M
000: Single-shot output mode
001: Delayed single-shot output mode
010: Continuous output mode
011: PWM output mode
TIO6 operation mode select bit
100: Measure clear input mode
101: Measure free-run input mode
110: Noise processing input mode
111: – ditto –
Note: • Operation mode can only be set or changed while the counter is inactive.
32180 Group User’s Manual (Rev.1.0)
10-107