MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timers
10
TIN5–8 Input Processing Control Register (TIN58CR)
<Address: H’0080 0214>
b0
0
1
0
2
TIN8S
0
3
0
4
0
5
0
6
TIN7S
0
7
0
8
0
9
0
10
TIN6S
0
11
0
12
0
13
0
14
TIN5S
0
b15
0
<After reset: H’0000>
b
Bit Name
Function
R
0
W
0
0
No function assigned. Fix to "0".
1–3
TIN8S
000: Disable input
001: Rising edge
010: Falling edge
011: Both edges
100: Low level
R
W
TIN8 input processing select bit
101: Low level
110: High level
111: High level
4
No function assigned. Fix to "0".
0
0
5–7
TIN7S
000: Disable input
001: Rising edge
010: Falling edge
011: Both edges
100: Low level
R
W
TIN7 input processing select bit
101: Low level
110: High level
111: High level
8
No function assigned. Fix to "0".
0
0
9–11
TIN6S
000: Disable input
001: Rising edge
010: Falling edge
011: Both edges
100: Low level
R
W
TIN6 input processing select bit
101: Low level
110: High level
111: High level
12
13–15
No function assigned. Fix to "0".
0
0
TIN5S
000: Disable input
001: Rising edge
010: Falling edge
011: Both edges
100: Low level
R
W
TIN5 input processing select bit
101: Low level
110: High level
111: High level
Note: • This register must always be accessed in halfwords.
32180 Group User’s Manual (Rev.1.0)
10-22