MULTIJUNCTION TIMERS
10.2 Common Units of Multijunction Timers
10
TIN0–4 Input Processing Control Register (TIN04CR)
<Address: H’0080 0212>
b0
0
1
0
2
3
0
4
0
5
0
6
7
0
8
0
9
0
10
0
11
TIN2S
12
0
13
TIN1S
14
0
b15
TIN0S
TIN4S
0
TIN3S
0
0
0
0
<After reset: H’0000>
b
Bit Name
Function
R
0
W
0
0
No function assigned. Fix to "0".
1–3
TIN4S
000: Disable input
001: Rising edge
010: Falling edge
011: Both edges
100: Low level
R
W
TIN4 input processing select bit
101: Low level
110: High level
111: High level
4
No function assigned. Fix to "0".
0
0
5–7
TIN3S
000: Disable input
001: Rising edge
010: Falling edge
011: Both edges
100: Low level
R
W
TIN3 input processing select bit
101: Low level
110: High level
111: High level
8,9
No function assigned. Fix to "0".
0
0
10,11
TIN2S
00: Disable input
01: Rising edge
10: Falling edge
11: Both edges
R
W
TIN2 input processing select bit
12,13
14,15
TIN1S
00: Disable input
01: Rising edge
10: Falling edge
11: Both edges
R
R
W
W
TIN1 input processing select bit
TIN0S
00: Disable input
01: Rising edge
10: Falling edge
11: Both edges
TIN0 input processing select bit
Note: • This register must always be accessed in halfwords.
32180 Group User’s Manual (Rev.1.0)
10-21