MULTIJUNCTION TIMERS  
10.2 Common Units of Multijunction Timers  
10  
10.2.3 Clock Bus and Input/Output Event Bus Control Unit  
(1) Clock bus  
The clock bus is provided for supplying clock to each timer, and is comprised of four lines of clock bus 0–3.  
Each timer can use these clock bus signals as clock input signals. The table below lists the signals that can  
be fed into the clock bus.  
Table 10.2.1 Acceptable Clock Bus Signals  
Clock Bus  
Acceptable Signal  
3
2
1
0
TCLK0 input  
Internal prescaler (PRS2) or TCLK3 input  
Internal prescaler (PRS1)  
Internal prescaler (PRS0)  
(2) Input event bus  
The input event bus is provided for supplying a count enable signal or measure capture signal to each timer,  
and is comprised of four lines of input event bus 0–3. Each timer can use these input event bus signals as  
enable (or capture) input. Furthermore, they can also be used as request signals to start A-D conversion or  
DMA transfer.  
The table below lists the signals that can be fed into the input event bus.  
Table 10.2.2 Connectable (Acceptable) Input Event Bus Signals  
Input Event Bus  
Connectable (Acceptable) Signal (Note 1)  
TIN3 input, output event bus 2 or TIO7 underflow signal  
TIN0 input, TIN2 input or TIN4 input  
TIO6 underflow signal  
3
2
1
0
TIO5 underflow signal  
Note 1: For the destination (output) to which the input event bus signals are connected, see Figure 10.1.1, “Block Diagram of MJT.”  
(3) Output event bus  
The output event bus has the underflow signal from each timer connected to it, and is comprised of four lines  
of output event bus 0–3. Output event bus signals are connected to output flip-flops, and can also be con-  
nected to the A-D converter and DMAC. Furthermore, output event bus 2 can be connected to input event  
bus 3.  
The table below lists the signals that can be connected to the output event bus.  
Table 10.2.3 Connectable (Acceptable) Output Event Bus Signals  
Input Event Bus  
Connectable (Acceptable) Signal (Note 1)  
TOP8, TIO3, TIO4 or TIO8 underflow signal  
TOP9 or TIO2 underflow signal  
3
2
1
0
TOP7 or TIO1 underflow signal  
TOP6 or TIO0 underflow signal  
Note 1: For the destination (output) to which the output event bus signals are connected, see Figure 10.1.1, “Block Diagram  
of MJT.”  
Note that the signals from each timer to the output event bus (and TIO5, 6 signals to the input event bus) are  
generated with the timing shown in Table 10.2.4, and not the timing at which signals are output from the timer  
to the output flip-flop.  
32180 Group User’s Manual (Rev.1.0)  