M16C/62P Group (M16C/62P, M16C/62PT)
5. Electrical Characteristics
VCC1=VCC2=5V
Timing Requirements
(VCC1 = VCC2 = 5V, VSS = 0V, at Topr = −40 to 85°C (T version) / −40 to 125°C (V version) unless otherwise
specified)
Table 5.66
Timer B Input (Counter Input in Event Counter Mode)
Standard
Symbol
Parameter
Unit
Min.
100
40
Max.
tc(TB)
TBiIN Input Cycle Time (counted on one edge)
ns
ns
ns
ns
ns
ns
tw(TBH)
tw(TBL)
tc(TB)
TBiIN Input HIGH Pulse Width (counted on one edge)
TBiIN Input LOW Pulse Width (counted on one edge)
TBiIN Input Cycle Time (counted on both edges)
TBiIN Input HIGH Pulse Width (counted on both edges)
TBiIN Input LOW Pulse Width (counted on both edges)
40
200
80
tw(TBH)
tw(TBL)
80
Table 5.67
Timer B Input (Pulse Period Measurement Mode)
Standard
Symbol
Parameter
Unit
Min.
400
200
200
Max.
Max.
Max.
tc(TB)
TBiIN Input Cycle Time
ns
ns
ns
tw(TBH)
tw(TBL)
TBiIN Input HIGH Pulse Width
TBiIN Input LOW Pulse Width
Table 5.68
Timer B Input (Pulse Width Measurement Mode)
Standard
Symbol
Parameter
Unit
Min.
400
200
200
tc(TB)
TBiIN Input Cycle Time
ns
ns
ns
tw(TBH)
tw(TBL)
TBiIN Input HIGH Pulse Width
TBiIN Input LOW Pulse Width
Table 5.69
A/D Trigger Input
Standard
Symbol
Parameter
Unit
Min.
tc(AD)
1000
ns
ns
ADTRG Input Cycle Time
tw(ADL)
125
ADTRG input LOW Pulse Width
Table 5.70
Serial Interface
Standard
Symbol
Parameter
Unit
Min.
200
100
100
Max.
80
tc(CK)
CLKi Input Cycle Time
CLKi Input HIGH Pulse Width
CLKi Input LOW Pulse Width
TXDi Output Delay Time
TXDi Hold Time
ns
ns
ns
ns
ns
ns
ns
tw(CKH)
tw(CKL)
td(C-Q)
th(C-Q)
tsu(D-C)
th(C-D)
0
RXDi Input Setup Time
RXDi Input Hold Time
70
90
Table 5.71
External Interrupt INTi Input
Standard
Symbol
Parameter
Unit
Min.
250
Max.
tw(INH)
tw(INL)
ns
ns
INTi Input HIGH Pulse Width
INTi Input LOW Pulse Width
250
Rev.2.41 Jan 10, 2006 Page 91 of 96