 浏览型号HD6417750SBP200的Datasheet PDF文件第352页浏览型号HD6417750SBP200的Datasheet PDF文件第353页浏览型号HD6417750SBP200的Datasheet PDF文件第354页浏览型号HD6417750SBP200的Datasheet PDF文件第355页浏览型号HD6417750SBP200的Datasheet PDF文件第357页浏览型号HD6417750SBP200的Datasheet PDF文件第358页浏览型号HD6417750SBP200的Datasheet PDF文件第359页浏览型号HD6417750SBP200的Datasheet PDF文件第360页  
12.3  
Operation  
Each channel has a 32-bit timer counter (TCNT) that performs count-down operations, and a 32-  
bit timer constant register (TCOR). The channels have an auto-reload function that allows cyclic  
count operations, and can also perform external event counting. Channel 2 also has an input  
capture function.  
12.3.1 Counter Operation  
When one of bits STR0–STR4 is set to 1 in the timer start register (TSTR, TSTR2), the timer  
counter (TCNT) for the corresponding channel starts counting. When TCNT underflows, the UNF  
flag is set in the corresponding timer control register (TCR). If the UNIE bit in TCR is set to 1 at  
this time, an interrupt request is sent to the CPU. At the same time, the value is copied from  
TCOR into TCNT, and the count-down continues (auto-reload function).  
Example of Count Operation Setting Procedure: Figure 12.2 shows an example of the count  
operation setting procedure.  
1. Select the count clock, for channel 0, 1, or 2, with bits TPSC2–TPSC0 in the timer control  
register (TCR). When an external clock is selected, set the TCLK pin to input mode with the  
TCOE bit in TOCR, and select the external clock edge with bits CKEG1 and CKEG0 in TCR.  
2. Specify whether an interrupt is to be generated on TCNT underflow with the UNIE bit in TCR.  
3. When the input capture function is used, set the ICPE bits in TCR, including specification of  
whether the interrupt function is to be used.  
4. Set a value in the timer constant register (TCOR).  
5. Set the initial value in the timer counter (TCNT).  
6. Set the STR bit to 1 in the timer start register (TSTR, TSTR2) to start the count.  
Rev. 6.0, 07/02, page 304 of 986  