THREE-PHASE WAVEFORM MODE
10.4 Three-phase mode 1
Continued from the preceding page.
Check whether the timer Ai interrupt request bit is “1” or not.
(Note that the first one-shot pulse width of timer Ai must be
the maximum among those of timers A0 through A2.)
Waiting for the dead time, which
was previously set, to elapse
❈ The output level is stabilized.
Setting of timer A3 interrupt priority level
b7
b0
Timer A3 interrupt control
register (address 7816
0
)
Timer A3 interrupt priority level
Set to one of levels 1 through 7.
No interrupt request
Three-phase waveform output is enabled.
b7
b0
Waveform output mode register
(address A616
1
)
Three-phase waveform output
is enabled.
Three-phase waveform output starts.
Fig. 10.4.2 Initial setting example for registers relevant to three-phase mode 1 (2)