Specifications (typical at nominal input and 25°C unless otherwise noted)
Line Regulation (LL-HL at full load)
Single
Dual
0.2%
0.5%
0.5%
Load Regulation (25% to 100% FL)
Single
Dual
1%
(only 2.5Vout)
1.5%
Cross Regulation (asymmetrical load 25%/100% FL)
Ripple and Noise (20MHz bandwith)
Temperature Coefficient
5%
85mVp-p
0.02%/°C, max.
300µS
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
2.5V
3.3V
3.9V
3.9V
5V
12V
6.2V
15V
15V
18V
Over Load Protection (% of full load at nominal Vin)
Short Circuit Protection
Efficiency
150% typ
Continuous, automatic recovery
see „Selection Guide“ table
Isolation Voltage
In to out
1.600VDC min.
1.600VDC min.
I/O to case
Isolation Resistance
Isolation Capacitance
Operating Frequency
Operating Temperature Range
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance
Thermal Shock
109 Ω min.
1200pF max.
400kHz typ.
-40°C to +85°C(with derating)
+100°C
-55°C to +105°C
Natural convection
20°C/Watt
MIL-STD-810D
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
5% to 95% RH
Relative Humidity
Case Material
Nickel-Coated copper
Non-conductive black plastic
Epoxy (UL94-V0)
Base Material
Potting Material
Conducted Emissions
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
EN55022
EN55022
Class A
Class A
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Conducted Immunity
Weight
18g
31.8 x 20.3 x 10.2mm
2.750 x 106 Hours
Dimensions
MTBF (see note 2)
218
April-2005