 浏览型号M38510/10104BGA的Datasheet PDF文件第10页浏览型号M38510/10104BGA的Datasheet PDF文件第11页浏览型号M38510/10104BGA的Datasheet PDF文件第12页浏览型号M38510/10104BGA的Datasheet PDF文件第13页浏览型号M38510/10104BGA的Datasheet PDF文件第15页浏览型号M38510/10104BGA的Datasheet PDF文件第16页浏览型号M38510/10104BGA的Datasheet PDF文件第17页浏览型号M38510/10104BGA的Datasheet PDF文件第18页  
MIL-M-38510/101J  
TABLE II. Electrical test requirements.  
MIL-PRF-38535  
test requirements  
Subgroups (see table III)  
Class S  
devices  
Class B  
devices  
Interim electrical parameters  
Final electrical test parameters 1/  
Group A test requirements  
1
1
1,2,3,4  
1,2,3,4  
1,2,3,4,5,6,  
7,8A,8B,12,  
13A,13B  
1,2,3,4,5,6,7  
Group C end point electrical  
parameters  
1,2,3, and  
table IV delta  
limits  
1 and table IV  
delta limits  
Additional electrical subgroups  
For group C periodic inspections  
Group D end point electrical  
parameters  
Not applicable  
8A,8B,12,  
13A,13B  
1
1,2,3  
1/ PDA applies to subgroup 1.  
4. VERIFICATION.  
4.1 Sampling and inspection. Sampling and inspection procedures shall be in accordance with MIL-PRF-38535 or as  
modified in the device manufacturer’s Quality Management (QM) plan. The modification in the QM plan shall not affect the  
form, fit, or function as function as described herein.  
4.2 Screening. Screening shall be in accordance with MIL-PRF-38535, and shall be conducted on all devices prior to  
qualification and quality conformance inspection. The following additional criteria shall apply:  
a. The burn-in test duration, test condition, and test temperature, or approved alternatives shall be as specified in the  
device manufacturer's QM plan in accordance with MIL-PRF-38535. The burn-in test circuit shall be maintained  
under document control by the device manufacturer's Technology Review Board (TRB) in accordance with  
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit  
shall specify the inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent  
specified in test method 1015 of MIL-STD-883.  
b. Interim and final electrical test parameters shall be as specified in table II, except interim electrical parameters test  
prior to burn-in is optional at the discretion of the manufacturer.  
c. Additional screening for space level product shall be as specified in MIL-PRF-38535.  