FM24V02 - 256Kb I2C FRAM
By Master
Start
Address & Data
Stop
S
Slave Address
0 A
Address MSB
A
Address LSB
A
Data Byte
A
P
By FM24V05
Acknowledge
Figure 5. Single Byte Write
Start
By Master
S
By FM24V05
Slave Address
0 A
Address & Data
Stop
Address MSB
A
Address LSB
A
Data Byte
A
Data Byte
A
P
Acknowledge
Figure 6. Multiple Byte Write
There are four ways to properly terminate a read
operation. Failing to properly terminate the read will
most likely create a bus contention as the FM24V02
attempts to read out additional data onto the bus. The
four valid methods are:
1.
The bus master issues a no-acknowledge in the
9
th
clock cycle and a stop in the 10
th
clock cycle.
This is illustrated in the diagrams below. This is
preferred.
The bus master issues a no-acknowledge in the
9
th
clock cycle and a start in the 10
th
.
The bus master issues a stop in the 9
th
clock
cycle.
The bus master issues a start in the 9
th
clock
cycle.
Read Operation
There are two basic types of read operations. They
are current address read and selective address read. In
a current address read, the FM24V02 uses the
internal address latch to supply the address. In a
selective read, the user performs a procedure to set
the address to a specific value.
Current Address & Sequential Read
As mentioned above the FM24V02 uses an internal
latch to supply the address for a read operation. A
current address read uses the existing value in the
address latch as a starting place for the read
operation. The system reads from the address
immediately following that of the last operation.
To perform a current address read, the bus master
supplies a slave address with the LSB set to a ‘1’.
This indicates that a read operation is requested.
After receiving the complete slave address, the
FM24V02 will begin shifting out data from the
current address on the next clock. The current address
is the value held in the internal address latch.
Beginning with the current address, the bus master
can read any number of bytes. Thus, a sequential read
is simply a current address read with multiple byte
transfers. After each byte the internal address counter
will be incremented.
Each time the bus master acknowledges a byte,
this indicates that the FM24V02 should read out
the next sequential byte.
2.
3.
4.
If the internal address reaches FFFFh, it will wrap
around to 0000h on the next read cycle. Figures 7 and
8 below show the proper operation for current
address reads.
Selective (Random) Read
There is a simple technique that allows a user to
select a random address location as the starting point
for a read operation. This involves using the first
three bytes of a write operation to set the internal
address followed by subsequent read operations.
To perform a selective read, the bus master sends out
the slave address with the LSB set to 0. This specifies
a write operation. According to the write protocol,
the bus master then sends the address bytes that are
loaded into the internal address latch. After the
FM24V02 acknowledges the address, the bus master
Rev. 0.1
Mar. 2009
Page 6 of 15