Figure 4-1 Suggested Communications Flow  
Power On or Hardware Reset  
0x0F  
Get  
'Last command'  
0x0E  
Setups CRC  
Check  
0x01  
Load Setups  
Block  
0x04  
Force Reset  
0xF0  
returned  
Setups CRC  
failed 1x  
0xF0 not  
returned  
CRC is OK  
No key,  
no error  
Setups CRC failed 2x  
0x06  
Report 1st Key  
~10ms Delay  
0x05  
Get  
General Status  
Any Error Flag  
(highest  
precedence)  
2 Keys  
Detected  
m
0x0F  
Get  
Only 1 Key  
in Detect  
Comms  
Error  
'Last command'  
(clear error)  
0x07  
Report all  
detections  
Keys OK  
eeprom corrupt, or  
calibration fail, or  
FMEA fail, or  
Internal Host  
Processes  
multiple errors  
resolvable  
error  
Key Detection(s) Processing  
Error Handling  
Comms with  
QT  
FMEA Calibration  
Error  
Stuck Key  
Detected  
Error  
Note: CRC errors or incorrect  
responses should cause  
each transmission to retry  
Done  
0x0B  
0x0C  
Get  
FMEA Status  
0xck  
Cal Key 'k'  
Get  
Errors for All  
Keys  
where changes are specifically required, such as for sensitivity,  
timing, or AKS changes.  
Error handling takes place whenever an error flag is detected,  
or the device stops communicating (not shown). The error  
handling procedure is up to the designer, however normally this  
would entail shutting down the product if the error is serious  
enough (for example, a key that will not calibrate, or a FMEA  
class error).  
The circles in this drawing are communications interchanges  
between host and sensor. The rectangles are internal host  
states or processing events. If any communications exchange  
fails, either the device will fail to respond within the allotted time,  
or the response CRC will be incorrect, or the response will be  
out of context (the response is clearly not for the intended  
command). In these cases the host should just repeat the  
command.  
Normally it is not required to reload the setups, since the device  
itself stores a backup copy of these in Flash memory should the  
eeprom become corrupt. However the host should reset the QT  
so that the device will copy the Flash setups to eeprom, and  
then the QT should check that the eeprom CRC code is correct.  
Only if this fails should the eeprom be reloaded by the host.  
One exception to this rule is just after powerup, since a CRC  
error in the eeprom setups at this point is clearly a critical error  
that would require reloading. This happens at the factory, during  
the very first powerup cycle.  
The control flow will spend 99% of its time alternating between  
the two states within the dashed rectangle. If a key is detected,  
the control flow will enter ‘Key Detection Processing’.  
Stuck Key Detection processing (0xck) is optional, since the  
device contains the max on-duration timeout function and can  
therefore recalibrate the stuck key automatically. However, the  
host can recalibrate stuck keys with greater flexibility if the  
recalibration timeouts are set to infinite and the host recalibrates  
them under specific conditions.  
The ‘Last Command’ command can be used at any time to clear  
comms error flags and to resynchronize failed communications,  
for example due to timing errors etc.  
lQ  
17  
QT60486-AS R8.01/0105  