C is the load Cx. If the series-R or Cx is too large, sensitivity  
will be reduced.  
5. Route sense traces away from other traces or wires that  
are connected to other circuits.  
Directly placing semiconductor transient protection devices  
or MOV's on the sense leads is not advised; these devices  
have extremely large amounts of non-linear parasitic C,  
which will swamp the capacitance of the electrode and may  
deliver spurious sensing results.  
6. Sense electrodes should be kept away from other  
circuits and grounds which are not directly connected to  
the sensor’s own circuit ground; other grounds will  
appear to float at high frequencies and couple RF  
currents into the sense lines.  
7. Keep the Cs sampling capacitors and all series-R  
components close to the IC.  
5.4 RF Susceptibility  
PCB layout, grounding, and the structure of the input circuitry  
have a great bearing on the success of a design that can  
withstand strong RF interference. The circuit is remarkably  
immune to RFI provided that certain design rules are  
adhered to:  
8. Use a 0.1µF minimum, ceramic bypass cap very close to  
the VSS/VDD supply pins.  
9. Use series-R’s in the sense line of as large a value as  
the circuit can tolerate without degrading sensitivity  
appreciably (see Section 1.2).  
1. Use SMT components to minimize lead lengths.  
2. Connect electrodes to SNS1, not SNS2.  
10. Bypass input power to chassis ground and again at  
circuit ground to reduce line-injected noise effects.  
Ferrites over the power wiring may be required to  
attenuate line injected noise.  
3. Use a ground plane under and around the circuit and  
along the sense lines, that is as unbroken as possible  
except for relief under and beside the sense lines to  
reduce total Cx. Relieved rear ground planes along the  
SNS lines should be ‘mended’ by bridging over them at  
1cm intervals with 0.5mm ‘rungs’ like a ladder.  
Achieving RF immunity requires diligence and a good  
working knowledge of grounding, shielding, and layout  
techniques. Very few projects involving these devices will fail  
EMC tests once properly constructed.  
4. Ground planes and traces should be connected only to a  
common point near the VSS pin of the IC.  