 浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第32页浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第33页浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第34页浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第35页浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第37页浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第38页浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第39页浏览型号HYB18L256160BCX-7.5的Datasheet PDF文件第40页  
HY[B/E]18L256160B[C/F]X-7.5  
256-Mbit Mobile-RAM  
Functional Description  
2.4.10  
POWER DOWN  
Power-down is entered when CKE is registered LOW  
(no accesses can be in progress). If power-down  
occurs when all banks are idle, this mode is referred to  
as precharge power-down; if power-down occurs when  
there is a row active in any bank, this mode is referred  
to as active power-down. Entering power-down  
deactivates the input and output buffers, excluding CLK  
and CKE. CKE LOW must be maintained during power-  
down.  
#,+  
#+%  
#3  
2!3  
#!3  
7%  
Power-down duration is limited by the refresh  
requirements of the device (tREF).  
!ꢂꢎ!ꢀꢁ  
"!ꢂꢏ"!ꢀ  
The power-down state is synchronously exited when  
CKE is registered HIGH (along with a NOP or  
DESELECT command). One clock delay is required for  
power down entry and exit.  
ꢒ $ONgT #ARE  
Figure 45 Power Down Entry Command  
#,+  
T20  
#+%  
02%  
./0  
./0  
./0  
6ALI  
6ALI  
6ALI  
#OMMAN  
!
RESS  
0RE !LL  
!ꢀꢂ ꢌ!0ꢍ  
$1  
(IGH:  
0OWER $OWN  
%NTRY  
%XIT FROM  
0OWER $OWN  
!NY  
#OMMAN  
0RECHARGE 0OWER $OWN MO E SHOWNALL BANKS ARE I LE AN T20 MET  
WHEN 0OWER $OWN %NTRY #OMMAN IS ISSUE  
ꢒ $ONgT #ARE  
Figure 46 Power Down Entry and Exit  
2.4.10.1 DEEP POWER DOWN  
The deep power down mode is an unique function on Low Power SDRAM devices with extremely low current  
consumption. Deep power down mode is entered using the BURST TERMINATE command (cf. Figure 35) except  
that CKE is LOW. All internal voltage generators inside the device are stopped and all memory data is lost in this  
mode. To enter the deep power down mode all banks must be precharged.  
The deep power down mode is asynchronously exited by asserting CKE HIGH. After the exit, the same command  
sequence as for power-up initialization, including the 200µs initial pause, has to be applied before any other  
command may be issued (cf. Figure 3 and Figure 4).  