型号: TNY279PG
PDF下载: 下载PDF文件 查看货源
内容描述: 能源艾菲cient ,离线式开关采用增强的灵活性和扩展功率范围 [Energy-Effi cient, Off-Line Switcher With Enhanced Flexibility and Extended Power Range]
分类和应用: 开关光电二极管
文件页数/大小: 24 页 / 1030 K
品牌: POWERINT [ Power Integrations ]
 浏览型号TNY279PG的Datasheet PDF文件第1页浏览型号TNY279PG的Datasheet PDF文件第2页浏览型号TNY279PG的Datasheet PDF文件第3页浏览型号TNY279PG的Datasheet PDF文件第4页浏览型号TNY279PG的Datasheet PDF文件第6页浏览型号TNY279PG的Datasheet PDF文件第7页浏览型号TNY279PG的Datasheet PDF文件第8页浏览型号TNY279PG的Datasheet PDF文件第9页  
TNY274-280  
In a typical implementation, the EN/UV pin is driven by an  
optocoupler. The collector of the optocoupler transistor is  
connected to the EN/UV pin and the emitter is connected to the  
SOURCE pin. The optocoupler LED is connected in series with  
a Zener diode across the DC output voltage to be regulated.  
When the output voltage exceeds the target regulation voltage  
level (optocoupler LED voltage drop plus Zener voltage), the  
optocoupler LED will start to conduct, pulling the EN/UV pin  
low. The Zener diode can be replaced by a TL43ꢀ reference  
circuit for improved accuracy.  
ON/OFF Operation with Current Limit State Machine  
The internal clock of the TinySwitch-III runs all the time. At the  
beginning of each clock cycle, it samples the EN/UV pin to  
decide whether or not to implement a switch cycle, and based  
on the sequence of samples over multiple cycles, it determines  
the appropriate current limit. At high loads, the state machine  
sets the current limit to its highest value. At lighter loads, the  
state machine sets the current limit to reduced values.  
V
V
EN  
EN  
CLOCK  
CLOCK  
DC  
DC  
MAX  
MAX  
I
I
DRAIN  
DRAIN  
V
V
DRAIN  
DRAIN  
PI-2749-082305  
PI-2667-082305  
Figure 6. Operation at Near Maximum Loading.  
Figure 7. Operation at Moderately Heavy Loading.  
V
V
EN  
EN  
CLOCK  
CLOCK  
DC  
DC  
MAX  
MAX  
I
I
DRAIN  
DRAIN  
V
V
DRAIN  
DRAIN  
PI-2661-082305  
PI-2377-082305  
Figure 9. Operation at Very Light Load.  
Figure 8. Operation at Medium Loading.  
5
www.powerint.com  