LNK500  
Conditions  
SOURCE = 0 V; TJ = -40 to 125 °C  
See Figure 12  
Parameter  
Symbol  
Min  
Typ  
Max  
Units  
(Unless Otherwise Specified)  
OUTPUT  
TJ = 25 °C  
ID = 25 mA  
28  
42  
32  
48  
ON-State  
Resistance  
RDS(ON)  
TJ = 100 °C  
OFF-State Drain  
Leakage Current  
VC = 6.2 V  
VD = 560 V, TA = 125 °C  
IDSS  
50  
µA  
V
See Note B  
VC = 6.2 V, TA = 25 °C  
BVDSS  
700  
36  
Breakdown Voltage  
DRAIN Supply  
Voltage  
See Note E  
50  
V
NOTES:  
A. For specifications with negative values, a negative temperature coefficient corresponds to an increase in magnitude with  
increasing temperature, and a positive temperature coefficient corresponds to a decrease in magnitude with increasing  
temperature.  
B. Breakdown voltage may be checked against minimum BVDSS specification by ramping the DRAIN pin voltage up to but not  
exceeding minimum BVDSS  
.
C. IC is increased gradually to obtain maximum current limit at di/dt of 90 mA/µs. Increasing IC further would terminate the cycle  
through duty cycle control.  
D. This parameter is normalized to IDCT to correlate to power supply output current (it is multiplied by IDCT(nominal)/IDCT).  
E. It is possible to start up and operate LinkSwitch at DRAIN voltages well below 36 V. However, the CONTROL pin charging  
current is reduced, which affects start-up time, auto-restart frequency, and auto-restart duty cycle. Refer to the characteristic  
graph on CONTROL pin charge current (IC) vs. DRAIN voltage (Figure 13) for low voltage operation characteristics.  
D
2/05 13  