7-Feb-2006
EP-91 12 V, 1 A, Universal Input Supply
12 Line Surge
Differential input line surge (1.2/50 µs) testing was completed on a single test unit to
IEC61000-4-5. Input voltage was set at 230 VAC / 60 Hz. Output was loaded at full load
and operation was verified following each surge event.
Surge
Voltage
Generator
Impedance
Phase Angle
Number of Strikes
Test Result
1 kV
Differential
90˚
2 Ω
10
PASS
2 kV
Common
Mode
90˚
12 Ω
10
PASS
Unit passed under all test conditions.