EP-91 12 V, 1 A, Universal Input Supply
11.2 Output Voltage Start-Up Profile
Start-up into full resistive load and no-load were both verified. A 12 Ω resistor was used
for the load, to maintain 1 A under steady-state conditions.
Figure 16 – Start-Up Profile, 115 VAC.
Fast trace is no-load rise time
Slower trace is maximum load (12 Ω)
2 V, 5 ms / div.
Figure 17 – Start-Up Profile, 230 VAC.
Fast trace is no-load rise time
Slower trace is maximum load (12 Ω)
2 V, 5 ms / div.
11.3 Drain Voltage and Current Start-Up Profile
Figure 18 – 90 VAC Input and Maximum Load.
Upper: VDRAIN, 100 V & 100 µs / div.
Lower: IDRAIN, 0.5 A / div.
Figure 19 – 265 VAC Input and Maximum Load.
Upper: VDRAIN, 200 V & 100 µs / div.
Lower: IDRAIN, 0.5 A / div.