13 Line Transient Testing
The power supply was tested for 1.2/50 µsec common mode and differential mode line
surge at 230 VAC, full load. The supply was mounted on a metal plate, and the output
was monitored with an LED to detect any output interruption. The power supply was
deemed to pass a test if it withstood the surge with no output interruption.
Differential Mode Surge, 2 ohm generator impedance, 10 strikes each setting at 30 sec
intervals
Surge Voltage
+3kV
-3kV
0° Phase Angle
Pass
90° Phase Angle
Pass
270° Phase Angle
Pass
Pass
Pass
Pass
Common Mode Surge, 12 ohm generator impedance, 10 strikes each setting at 30 sec
intervals
Surge Voltage
+4kV
-4kV
0° Phase Angle
Pass
90° Phase Angle
Pass
270° Phase Angle
Pass
Pass
Pass
Pass