ZM7300G Series Digital Power Manager
Data Sheet
Table 1. DPM Setup Registers
Address Register
Content
Register
Type
User
Access
Write
Protect
Initial Value
Offset1
Name
0x00
0x04
0x08
0x09
0x0A
0x0B
0x0C
0x0D
0x0E
0x0F
0x10
0x11
0x13
0x15
0x17
0x1B
0x1F
0x23
0x27
0x28
0x80
0x84
0x88
0x89
0x8B
0x8C
0x8D
0x8E
0x8F
0x91
0x95
0x96
GD1[3:0]
GD2[3:0]
GAC
GBC
GCC
GDC
FPC1
FPC2
EPC
Group Definition Register 1
Group Definition Register 2
Group A Configuration
Group B Configuration
Group C Configuration
Group D Configuration
Fault Propagation Configuration 1
Fault Propagation Configuration 2
Error Propagation Configuration
Interrupt Configuration 1
Interrupt Configuration 2
IBV Low threshold
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
Static
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
OTP
R/W
R/W
R/W
R/W
R/W
R/W
R
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
N/A
yes
yes
yes
yes
0x00000000
0x00000000
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
0x00
IC1
IC2
IBL[1:0]
IBH[1:0]
ID[1:0]
PB1[3:0]
PB2[3:0]
PB3[3:0]
PB4[3:0]
PMC
PID[31:0]
RTC[3:0]
PPS[3:0]
EST
IBV[1:0]
STA
STB
STC
STD
0x00
0xFF
IBV high threshold
DPM Customer Identification
Parallel Bus Register 1
Parallel Bus Register 2
Parallel Bus Register 3
Parallel Bus Register 4
Power Manager Configuration
POL Identification Register
Run Time Counter
0xFFFF
0x00000000
0x00000000
0x00000000
0x00000000
0x00
Static
Static
Static
yes
yes
0x00
Run time
Run time
Run time
Run time
Run time
Run time
Run time
Run time
Static
Read only
value at last shut-down
(4x) 0x00
0x00
POL Programming Status
Event Status
R
R
R
R
R
R
R
R
IB Voltage
Status of Group A
Status of Group B
Status of Group C
0x00
0x00
0x00
0x00
Status of Group D
0x00
REL[1:0]
PSS[3:0]
DPMS
WP
DPM Software Release
POL Status Summary
DPM Status
According to DPM type
0x00
Run time
Run time
Volatile
R
R
R/W
0x01
0x00
Write Protection
______________________________________
1
Writing into memory locations beyond address offset 0x96 must be avoided
The static registers are saved in the non-volatile memory and used to store the system configuration
data. The run-time registers contain status information and are evaluated during run-time. The Write
Protection register WP is a volatile register that defaults to write protect at power-up.
10.1.3 POL Setup Registers
Since the POL converters contain only RAM, the data defining performance parameters for each POL
and Auxiliary Device, such as the output voltage, protection thresholds, feedback loop compensation,
turn-on and turn-off delays, fault management settings, etc., is stored in the POL setup registers in the
DPM. The POL setup registers consist of 23 data bytes and 2 CRC bytes. The Auxiliary Device setup
registers occupy the same amount of bytes as a POL converter, but only 3 registers have meaningful
data. The other registers should be filled with 0x00. The POL setup registers are listed in Table 2.
ZD-00896 Rev. 5.1, 13-Jul-10
www.power-one.com
Page 10 of 33