欢迎访问ic37.com |
会员登录 免费注册
发布采购

CPD200-4530 参数 Datasheet PDF下载

CPD200-4530图片预览
型号: CPD200-4530
PDF下载: 下载PDF文件 查看货源
内容描述: 200 - 250瓦的CompactPCI DC- DC转换器 [200 - 250 Watt CompactPCI DC-DC Converters]
分类和应用: 转换器PC
文件页数/大小: 13 页 / 331 K
品牌: POWER-ONE [ POWER-ONE ]
 浏览型号CPD200-4530的Datasheet PDF文件第3页浏览型号CPD200-4530的Datasheet PDF文件第4页浏览型号CPD200-4530的Datasheet PDF文件第5页浏览型号CPD200-4530的Datasheet PDF文件第6页浏览型号CPD200-4530的Datasheet PDF文件第8页浏览型号CPD200-4530的Datasheet PDF文件第9页浏览型号CPD200-4530的Datasheet PDF文件第10页浏览型号CPD200-4530的Datasheet PDF文件第11页  
CPD Series Data Sheet
200 – 250 Watt CompactPCI
®
DC-DC Converters
®
Enable
Connect enable pin 27 (EN#) with signal return pin 22
(RTN) externally to start the converter. Pin 27 is shorter
than the others ensuring startup only when all other pins
are already connected to the system providing a true hot-
swap capability.
Temperature Warning and Shut-Down
The temperature warning circuitry monitors the case
temperature. Its output signal changes from high to low
impedance, when the case temperature exceeds the
upper threshold level, and changes back to high
impedance, when the case temperature falls below the
lower threshold level.
Pin 38 (degrade signal
V
DEG#
) is internally connected via
the collector-emitter path of an NPN transistor to the
signal return pin 22. The current
I
DEG#
through should not
exceed 40 mA. To prevent the NPN transistor from
damage,
V
DEG#
should not exceed 40 V.
If the case temperature
T
C
exceeds 105 °C, the converter
will be disabled. It resumes operation, once
T
C
falls below
105 °C.
11056a
Power Fail Signal
The power fail circuitry monitors the input voltage and all
output voltages. Its output signal
V
fail
changes from high to
low impedance, when one of the monitored voltages falls
below the threshold level;
V
fail
changes back to high
impedance, when the monitored voltage exceeds the
threshold level again.
The threshold levels correspond to approx. 90% of
V
i min
and approx. 85% of
V
o nom
.
Connector pin 42 (fail signal
V
fail
) is internally connected
via the drain-source path of a JFET (self-conducting type)
to the signal return pin 22. The current
I
fail
should not
exceed 2.5 mA. The JFET is not protected against
overvoltage;
V
fail
should not exceed 40 V.
11006a
46
Vo+
R
p
Input
42
FAL#
I
fail
V
fail
47
22
RTN
46
Vo+
R
p
Input
38
I
DEG#
DEG#
V
DEG#
Fig. 8
Power Fail: JFET output, I
fail
≤2.5
mA.
Sense Lines
(Only for Vo1, Vo2 and Vo3.)
This feature allows the compensation of voltage drops
across the connector contacts and if necessary, across
the load lines.
To ensure correct operation, each sense line (S+ and S–)
should be connected to its respective power output (Vo+
and Vo–).
Note:
All outputs have a common sense return.
47
22
RTN
Fig. 6
Degrade signal: NPN output V
DEG#
≤40
V, I
DEG#
≤20
mA
V
DEG#
[V]
10
8
6
4
2
0
60
70
80
90
100
110 °C
degrade signal
05189a
P
o
/P
o max
1
0.8
0.6
0.4
0.2
0
thermal shut-down
The voltage difference between any sense line at its re-
spective power output pin (as measured on the connector)
should not exceed the following values.
Table 7: Sense line data
Output
[V]
3.3
5
12
Total voltage difference between sense lines
and their respective outputs
0.8 V
1V
1V
Fig. 7
Degrade signal V
DEG#
versus case temperature T
C
Table 6: Degrade threshold level
Case Temperature
min
Threshold level
80 °C
typ
85 °C
max
90 °C
Note:
The output terminals Vo+ and Vo – must always be
connected to the load before connecting the sense lines S+
and S–, otherwise the converter will be damaged.
Note:
If the sense lines S+ and S– compensate for a
considerable voltage drop, the output loads shall be
reduced in order to respect the maximum output power.
Page 7 of 13
www.power-one.com