NSE-8G™ Standard Product Data Sheet
Preliminary
101xx : ports 31-30 on least significant bits
110xx : ports 5-0
111xx : ports 5-0
WORDADDR[13:0]
This field indicates the address of the update connection memory page to be accessed. This
field relates to the time location within the SBI/TeleCombus frame. I.e. Location 0 would be
the first A1 byte of the frame and location 24 is the C1 character.
This field is ignored in page copy mode. Valid values are 0-9719.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-2010850, Issue 1
90