NSE-8G™ Standard Product Data Sheet  
Preliminary  
18 Ordering and Thermal Information  
18.1 Packaging Information  
Part No.  
Description  
480 Uni Ball Grid Array (UBGA) Package  
PM8621-BIAP  
18.2 Thermal Information  
In full operation (10–12 ports), the NSE-8G is designed to operate over a wide  
temperature range when used with a heat sink with a worst case Junction to case  
Tj (Tjc) of 1 °C/W and is suited for industrial applications such as outside plant  
equipment  
Maximum long-term operating junction temperature to ensure adequate long-term life  
105 0C  
Maximum junction temperature for short-term excursions with guaranteed continued functional 125 0C  
1
performance. This condition will typically be reached when local ambient reaches 70 Deg C.  
Minimum ambient temperature  
-400C  
2
Ambient  
Device Compact Model  
ΘJC (0C/W)  
ΘJB (0C/W)  
# 1  
# 4  
SA  
Θ
Heat Sink  
Operating power is dissipated in package  
(watts) at worst case power supply  
Θ
CS  
Power (watts)  
2.56  
Case  
Θ
JC  
Device Compact  
Model  
ΘSA and ΘCS required for long-  
3
term operation  
Junction  
4
ΘSA + ΘCS (0C/W)  
#5  
Θ
JB  
Board  
Notes  
1. Short-term is understood as the definition stated in Telcordia Generic Requirements GR-63-Core  
2. ΘJC, the junction-to-case thermal resistance is a measured nominal value + 2 sigma. ΘJB, the junction-  
to-board thermal resistance is obtained by simulating conditions described in JEDEC Standard, JESD  
51  
3. ΘSA is the thermal resistance of the heat sink to ambient. ΘCS is the thermal resistance of the heat sink  
attached material  
4. The actual ΘSA required may vary according to the air speed at the location of the device in the system  
with all the components in place  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-2010850, Issue 1  