PM7385 FREEDM-84A672
DATA SHEET
PMC-1990114
ISSUE 6
84 LINK, 672 CHANNEL FRAME ENGINE AND DATA LINK MANAGER
WITH ANY-PHY PACKET INTERFACE
Register 0x034 : FREEDM-84A672 Master Tributary Loopback #2
Bit
Type
Function
Default
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 7
Bit 6
Bit 5
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
SPE2_LBEN[4]
SPE2_LBEN[3]
SPE2_LBEN[2]
SPE2_LBEN[1]
SPE1_LBEN[28]
SPE1_LBEN[27]
SPE1_LBEN[26]
SPE1_LBEN[25]
SPE1_LBEN[24]
SPE1_LBEN[23]
SPE1_LBEN[22]
SPE1_LBEN[21]
SPE1_LBEN[20]
SPE1_LBEN[19]
SPE1_LBEN[18]
SPE1_LBEN[17]
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
This register controls line loopback for tributaries #17 to #28 of SPE #1 and
tributaries #1 to #4 of SPE #2.
SPE1_LBEN[28:17]:
The SPE #1 loopback enable bits (SPE1_LBEN[28:17]) control line loopback
for tributaries #28 to #17 of SPE #1 of the SBI Interface. When
SPE1_LBEN[n] is set high, the data on tributary #n output by the SBI PISO
block is looped back to the tributary #n input of the SBI SIPO block. When
SPE1_LBEN[n] is set low, transmit data for tributary #n is provided by the
TCAS block (i.e. processed normally).
SPE2_LBEN[4:1]:
The SPE #2 loopback enable bits (SPE2_LBEN[4:1]) control line loopback for
tributaries #4 to #1 of SPE #2 of the SBI Interface. When SPE2_LBEN[n] is
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
83