UFDET:
The underflow detect bit (UFDET) indicates the status of the PMON Transmit FIFO Underflow
Count register. UFDET is set high when underflow events have occurred during the latest
PMON accumulation interval. UFDET is set low if no underflow events are detected.
C1DET:
The configurable event #1 detect bit (C1DET) indicates the status of the PMON Configurable
Count #1 register. C1DET is set high when selected events have occurred during the latest
PMON accumulation interval. C1DET is set low if no selected events are detected.
C2DET:
The configurable event #2 detect bit (C2DET) indicates the status of the PMON Configurable
Count #2 register. C2DET is set high when selected events have occurred during the latest
PMON accumulation interval. C2DET is set low if no selected events are detected.