RELEASED
PM7350 S/UNI-DUPLEX
DATA SHEET
PMC-1980581
ISSUE 5
DUAL SERIAL LINK PHY MULTIPLEXER
Register 0x34: RXD2 Extract FIFO Control
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Unused
Unused
Unused
Unused
Unused
X
X
X
X
X
X
0
Unused
R/W
R/W
UPF2OVRE
UPF2RST
0
UPF2RST:
The UPF2RST bit is used to reset the Microprocessor Cell Extract FIFO
associated with RXD2+/-. When UPF2RST is set to logic 0, the FIFO
operates normally. When UPF2RST is set to logic 1, all the FIFO is
immediately emptied and ignores writes. The FIFO remains empty and
continues to ignore writes until logic 0 is written to UPF2RST.
UPF2OVRE:
The UPF2OVRE bit enables the assertion of the INTB output due to an
overflow error condition of the Microprocessor Cell Extract FIFO associated
with RXD2+/-. When UPF2OVRE is set to logic 1, the interrupt is enabled.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
133