S/UNI-IMA-4 Telecom Standard Product Data Sheet  
Released  
The RDAT is not sensitive to the alignment of ICP cells within a group. There is no  
performance degradation even if all of the ICP cells in a group have the same offset.  
If the device is in Any-PHY mode or UTOPIA L2 Single Port mode, there is only a single FIFO  
shared among all of the groups. The RDAT ensures that no more than 16 cells are stored in the  
shared FIFO for a single group. If the S/UNI-IMA-4 is in UTOPIA L2 Multi-port mode, each  
group has its own FIFO. Note that each group does not have a dedicated buffer of 16 cells; the  
16 cell limit is used to prevent a small number of groups from monopolizing the shared FIFO  
depth. The shared FIFO is 124 cells deep.  
If the group FIFO is not emptied in a timely fashion, data is dropped; this is similar to the  
procedure used by any other PHY level device. The IDCC service request FIFO will always be  
serviced regardless of the state of the Group FIFO. For multi-port mode, if the respective Group  
FIFO is full, the cell will be dropped. In Any-PHY mode and UTOPIA L2 Single Port mode, if  
either the shared FIFO is full or there are already 16 cells for the current group in the FIFO, the  
cell will be dropped.  
Receive Statistics  
The RDAT will maintain statistics on a per-link basis during link data processing, and on a per-  
group basis during ATM data processing. These statistics may be accessed though the indirect  
ECBI register interface, and are defined in section 11.8. For the link statistics, eight statistics  
are provided. The OIF anomaly statistics may be incremented in addition to one and only one  
of the other seven statistics, as shown in the flow diagram in Figure 22.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its customers’ internal use.  
Document No.: PMC-2020889, Issue 2  
68