S/UNI-IMA-4 Telecom Standard Product Data Sheet  
Released  
Table 20 Receive ICP Cell Buffer Structure  
Word Bits Parameter  
Description  
icp_data  
Octets 6-53 of the payload contained in the last non-errored ICP cell  
for this link.  
31:24  
23:16  
15:8  
7:0  
0
1
Octet 6  
Octet 10  
Octet 7  
Octet 11  
Octet 8  
Octet 12  
Octet 9  
Octet 13  
2
Octet 14  
Octet 18  
Octet 22  
Octet 26  
Octet 30  
Octet 34  
Octet 38  
Octet 42  
Octet 46  
Octet 50  
Reserved.  
Octet 15  
Octet 19  
Octet 23  
Octet 27  
Octet 31  
Octet 35  
Octet 39  
Octet 43  
Octet 47  
Octet 51  
Octet 16  
Octet 20  
Octet 24  
Octet 28  
Octet 32  
Octet 36  
Octet 40  
Octet 44  
Octet 48  
Octet 52  
Octet 17  
Octet 21  
Octet 25  
Octet 29  
Octet 33  
Octet 37  
Octet 41  
Octet 45  
Octet 49  
Octet 53  
3
4
5
6
7
8
9
10  
11  
12  
31:10  
9
position_error  
The current ICP cell was received in an unexpected position within  
the IMA frame. If the contents of the cell are valid, then the ICP cell  
is considered valid, but the IFSM will transition to the IMA Hunt  
state.  
8
7
header_invalid  
cid_invalid  
The ATM cell header is not a correct ICP cell header. This bit  
should only be set when no ICP cells have been received on this  
link.  
The Cell ID does not indicate the OAM Cell Type is ICP. This bit  
should only be set when no ICP cells have been received on this  
link.  
6
5
label_invalid  
lid_mm  
The OAM Label does not indication IMA version 1.1.  
The link identifier in the current ICP cell does not match the LID in  
validation memory.  
4
3
2
1
ima_id_mm  
m_mm  
The IMA ID in the current ICP cell does not match the IMA ID in  
validation memory.  
The IMA Frame Length in the current ICP cell does not match the  
length in validation memory.  
seq_error  
The IMA Frame Sequence Number in the current ICP cell does not  
match the sequence number maintained by the RDAT.  
icp_offset_mm  
The ICP Cell Offset in the current ICP cell does not match the offset  
in validation memory.  