欢迎访问ic37.com |
会员登录 免费注册
发布采购

PM73487 参数 Datasheet PDF下载

PM73487图片预览
型号: PM73487
PDF下载: 下载PDF文件 查看货源
内容描述: 622 Mbps的ATM流量管理设备 [622 Mbps ATM Traffic Management Device]
分类和应用: 异步传输模式ATM
文件页数/大小: 251 页 / 2936 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM73487的Datasheet PDF文件第141页浏览型号PM73487的Datasheet PDF文件第142页浏览型号PM73487的Datasheet PDF文件第143页浏览型号PM73487的Datasheet PDF文件第144页浏览型号PM73487的Datasheet PDF文件第146页浏览型号PM73487的Datasheet PDF文件第147页浏览型号PM73487的Datasheet PDF文件第148页浏览型号PM73487的Datasheet PDF文件第149页  
Released  
Datasheet  
PM73487 QRT  
PMC-Sierra, Inc.  
PMC-980618  
Issue 3  
622 Mbps ATM Traffic Management Device  
Field (Bits)  
Description  
QE_RX_LOWER48_SCG_QD_NE  
1
The Rx Lower48 Service Class Group Queue Depth is negative. This is  
a non-recoverable state for the device. The device should be reset and  
reinitialized.  
G
(19)  
0
1
The Rx Lower48 Service Class Group Queue Depth is non-negative.  
QE_RX_LOWER32_SCG_QD_NE  
The Rx Lower32 Service Class Group Queue Depth is negative. This is  
a non-recoverable state for the device. The device should be reset and  
reinitialized.  
G
(18)  
0
1
The Rx Lower32 Service Class Group Queue Depth is non-negative.  
QE_RX_LOWER16_SCG_QD_NE  
The Rx Lower16 Service Class Group Queue Depth is negative. This is  
a non-recoverable state for the device. The device should be reset and  
reinitialized.  
G
(17)  
0
1
The Rx Lower16 Service Class Group Queue Depth is non-negative.  
QE_RX_DIR_QD_NEG  
(16)  
The Rx Direction Queue Depth is negative. This is a non-recoverable  
state for the device. The device should be reset and reinitialized.  
The Rx Direction Queue Depth is non-negative.  
0
Not Used (15)  
Driven with a 0  
QE_INVALID_CSTART  
(14)  
1
The internally generated Rx cell start did not arrive within 254  
SYSCLKs. This is a sign that the SECLK is absent or is running too  
slowly.  
0
1
The internally generated Rx cell start arrived within 254 SYSCLKs.  
QE_RX_SEQ_FAIL  
(13)  
An illegal state is present in the Rx Sequencing state machine. This is  
likely a non-recoverable state for the device. The device should be reset  
and reinitialized.  
0
1
The Rx Sequencing state machine is currently in a legal state.  
QE_TX_CH_QD_NEG  
(12)  
A Tx Channel Queue Depth is negative. This is a non-recoverable state  
for the device. The device should be reset and reinitialized.  
A Tx Channel Queue Depth is non-negative.  
0
1
QE_TX_SCQ_QD_NEG  
(11)  
A Tx Service Class Queue, Queue Depth is negative. This is a non-  
recoverable state for the device. The device should be reset and reinitial-  
ized.  
0
1
A Tx Service Class Queue, Queue Depth is non-negative.  
QE_TX_SC_QD_NEG  
(10)  
A Tx Service Class Queue Depth is negative. This is a non-recoverable  
state for the device. The device should be reset and reinitialized.  
A Tx Service Class Queue Depth is non-negative.  
0
1
QE_TX_VO_QD_NEG  
(9)  
A Tx Virtual Output Queue Depth is negative. This is a non-recoverable  
state for the device. The device should be reset and reinitialized.  
A Tx Virtual Output Queue Depth is non-negative.  
0
1
QE_RX_CH_QD_NEG  
(8)  
A Rx Channel Queue Depth is negative. This is a non-recoverable state  
for the device. The device should be reset and reinitialized.  
A Rx Channel Queue Depth is non-negative.  
0
1
QE_RX_SC_QD_NEG  
(7)  
A Rx Service Class Queue Depth is negative. This is a non-recoverable  
state for the device. The device should be reset and reinitialized.  
A Rx Service Class Queue Depth is non-negative.  
0
133  