S/UNI®-JET Data Sheet
Released
32
•
Provides programmable pseudo-random test sequence generation (up to 2 -1 bit length
sequences conforming to ITU-T O.151 standards). Diagnostic abilities include single bit error
-1
-7
insertion or error insertion at bit error rates ranging from 10 to 10 .
The bypass and loopback features of the S/UNI-JET:
•
•
•
Allow bypassing of the DS3, E3, and J2 framers to enable transmission system sublayer
processing by an external device.
Allow bypassing of the PLCP and ATM functions to enable use of the S/UNI-JET as a DS3,
E3, or J2 framer.
Provide diagnostic loopbacks, line loopbacks, and payload loopbacks.
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use
Document ID: PMC-1990267, Issue 3
20