PM7344 S/UNI-MPH  
DATA SHEET  
PMC-950449  
ISSUE 6  
MULTI-PHY USER NETWORK INTERFACE  
Pin Name  
Type  
Pin Function  
No.  
VSS_DC[3] Ground  
VSS_DC[2]  
115 DC Ground (VSS_DC[3:0]). These pins should  
85  
53  
21  
be connected to GND in common with  
VSS_AC[2:0].  
VSS_DC[1]  
VSS_DC[0]  
Notes on Pin Description:  
1. VDD_DC[3:0] and VSS_DC[3:0] are the +5 V and ground connections,  
respectively, for the core circuitry and the DC drive of the output pads of the  
device. VDD_AC[2:0] and VSS_AC[2:0] are the +5 V and ground  
connections, respectively, for the AC switching of the pad ring circuitry of the  
device. These power supply connections must all be utilized and must all  
connect to a common +5 V or ground rail, as appropriate. There is no low  
impedance connection within the S/UNI-MPH between the core, and pad ring  
supply rails. Failure to properly make these connections may result in  
improper operation or damage to the device.  
2. Inputs RSTB, TMS, TDI, TRSTB and ALE have integral pull-up resistors.  
3. The TDLSIG/TDLINT[4:1] pins have integral pull-up resistors and default to  
being inputs after a reset.  
4. D[7:0], TCLKO[4:1], RCLKO, RDAT[7:0], RCA[4:1], RXPRTY, RSOC,  
TCA[4:1], and the TCAMPH and RCAMPH bidirectionals have 4mA drive  
capability. All other outputs and bidirectionals have 2mA drive capability.  
5. All inputs and bidirectionals present minimum capacitive loading and operate  
at TTL logic levels.  
6. When an internal RFDL is enabled, the RDLINT[x] output goes high:  
1) when the number of bytes specified in the RFDL Interrupt Status/Control  
Register have been received on the data link,  
2) immediately on detection of RFDL FIFO buffer overrun,  
3) immediately on detection of end of message,  
4) immediately on detection of an abort condition, or,  
5) immediately on detection of the transition from receiving all ones to flags.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
38