PM7344 S/UNI-MPH
DATA SHEET
PMC-950449
ISSUE 6
MULTI-PHY USER NETWORK INTERFACE
Notes:
1. All OEN signals will set the corresponding bidirectional signal (the one
preceding the OEN in the boundary scan chain, see note 7 also) to an output
when set low.
2. Unused.
3. When set high, RDLCLK[4:1], RCA[4:1], TCA[4:1], and RCLKO will be set to
high-impedance.
4. When set high, TDP[4:1], TDN[4:1], TCLKO[4:1], TDLCLK[4:1] will be set to
high impedance.
5. When set high, RDLSIG[4:1] will be set to high impedance.
6. When set high, RDAT[7:0], RSOC, and RXPRTY will be set to high
impedance.
7. TFPI is the first bit of the boundary scan chain.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
224