PM7344 S/UNI-MPH
DATA SHEET
PMC-950449
ISSUE 6
MULTI-PHY USER NETWORK INTERFACE
Registers 03FH, 13FH, 23FH and 33FH: IBCD Deactivate Code
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
DACT7
DACT6
DACT5
DACT4
DACT3
DACT2
DACT1
DACT0
0
0
0
0
0
0
0
0
This 8 bit register selects the Deactivate code sequence that is to be detected. If
the code sequence length is less than 8 bits, the first 8 bits of several repetitions
of the code sequence must be used to fill the 8 bit register. For example, if code
sequence is a repeating 001, then the first 8 bits of three repetitions (001001001)
is programmed into the register, i.e.00100100. Note that bit DACT7 corresponds
to the first code bit received.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
145