PM7344 S/UNI-MPH
DATA SHEET
PMC-950449
ISSUE 6
MULTI-PHY USER NETWORK INTERFACE
Registers 025H, 125H, 225H and 325H: E1-FRMR Maintenance/Alarm Status
Interrupt Indication
Bit
Type
Function
Default
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
R
RRAI
Unused
AISDI
Unused
REDI
AISI
FEBEI
CRCEI
X
X
X
X
X
X
X
X
R
R
R
R
R
A logic 1 in any bit position of these registers indicates which maintenance or
alarm status has changed state.
RRAI, AISDI, REDI, and AISI:
RRAI, AISDI, REDI, and AISI indicate when the corresponding E1-FRMR
Maintenance/Alarm Status register bit has changed state from logic 0 to logic
1 or vice-versa. These bits are cleared when this register is read.
FEBEI:
The FEBEI bit becomes a logic one when a FEBE indication is received in the
Si bits of frames 13 or 15. This bit is cleared when this register is read.
CRCEI:
The CRCEI bit becomes a logic one when a calculated CRC differs from the
received CRC remainder. This bit is cleared when this register is read.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
123