S/UNI®-ATLAS-3200 Telecom Standard Product Data Sheet  
Preliminary  
Wr_PhyI  
When Wr_PhyI is logic 1, then a write access to the PHY Policing RAM will write to the  
PhyI field. When it is logic 0, the contents of PhyI will be unchanged after a write access.  
Wr_Reserved  
When Wr_Reserved is logic 1, then a write access to the PHY Policing RAM will write to the  
Reserved field. When it is logic 0, the contents of the Reserved field will be unchanged after  
a write access. These bits should be written to zero on setup and left alone thereafter.  
Wr_PhyNonComp1  
When Wr_PhyNonComp1 is logic 1, then a write access to the PHY Policing RAM will write  
to the PHY Non-Compliant Count 1 field. When it is logic 0, the contents of PHY Non-  
Compliant Count 1 will be unchanged after a write access.  
Wr_PhyNonComp2  
When Wr_PhyNonComp2 is logic 1, then a write access to the PHY Policing RAM will write  
to the PHY Non-Compliant Count 2 field. When it is logic 0, the contents of PHY Non-  
Compliant Count 2 will be unchanged after a write access.  
Wr_PhyNonComp3  
When Wr_PhyNonComp1 is logic 3, then a write access to the PHY Policing RAM will write  
to the PHY Non-Compliant Count 3 field. When it is logic 0, the contents of PHY Non-  
Compliant Count 3 will be unchanged after a write access.  
Wr_PhyConfig  
When Wr_PhyConfig is logic 1, then a write access to the PHY Policing RAM will write to  
the PHY Action, PHY Police Config, PHY VC Count, and PHY Policing Rollover FIFO  
Enable fields, as well as the 10 Unused bits in Row 3.. When it is logic 0, the contents of  
these fields will be unchanged after a write access.  
CLRONRD  
If the CLRONRD bit is logic 1, then the per-PHY non-compliant cell counts are cleared after  
a read access to a per-PHY Policing RAM location is performed. If CLRONRD is logic 0,  
then a clearing write is not performed when the per-PHY non-compliant cell counts are  
accessed.  
Proprietary and Confidential to PMC-Sierra, Inc., and for its Customers’ Internal Use  
Document ID: PMC-1990553, Issue 4  
253  