STANDARD PRODUCT  
PM5365 TEMAP  
DATASHEET  
PMC-1991148  
ISSUE 3  
HIGH DENSITY VT/TU MAPPER  
AND M13 MULTIPLEXER  
Tributary path BIP-2 errors are detected by comparing the tributary path BIP-2  
bits in the V5 byte extracted from the current multiframe, to the BIP-2 value  
computed for the previous multiframe. BIP-2 errors may be accumulated on a  
block or nibble basis as controlled by software configurable registers. Far end  
block errors (FEBEs) are detected by extracting the FEBE bit from the tributary  
path overhead byte (V5).  
Tributary path remote defect indication (RDI) and remote failure indication (RFI)  
are detected by extracting bit 8 and bit 4 respectively of the tributary path  
overhead byte (V5). The RDI is recognized when bit 8 of the V5 byte is set high  
for five or ten consecutive multiframes while RFI is recognized when bit 4 of V5  
is set high for five or ten consecutive frames. The RDI and RFI bits may be  
treated as a two-bit code word. A code change is only recognized when the code  
is unchanged for five or ten frames.  
The tributary path signal label (PSL) found in the tributary path overhead byte  
(V5) is processed. An incoming PSL is accepted when it is received unchanged  
for five consecutive multiframes. The accepted PSL is compared with the  
associated provisioned value. The PSL match/mismatch state and UNEQ  
(unequipped) state is determined by the following:  
Table 2  
- Path Signal Label Mismatch State  
Expected PSL  
Accepted PSL  
PSLM State  
UNEQ State  
(Unequipped)  
000  
000  
000  
000  
001  
000  
001  
PDI Code  
Match  
Inactive  
Inactive  
Inactive  
Inactive  
Mismatch  
Mismatch  
Mismatch  
Mismatch  
XXX U 000, 001, PDI Code  
000  
Active  
(unequipped)  
001  
001  
001  
001  
PDI Code  
Match  
Match  
Match  
Inactive  
Inactive  
Inactive  
XXX U 000, 001, PDI Code  
PDI Code  
000  
Mismatch  
Active  
(unequipped)  
PDI Code  
PDI Code  
PDI Code  
001  
PDI Code  
Match  
Match  
Mismatch  
Inactive  
Inactive  
Inactive  
XXX U 000, 001, PDI Code  
Proprietary and Confidential to PMC-Sierra, Inc. and for its Customers’ Internal Use  