PM5363 TUPP+622
TUPP+622
DATASHEET
PMC-1981421
ISSUE 4
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR FOR 622 MBIT/S
INTERFACES
TUGEN:
When set high, the TUGEN bit enables the processing of tributaries in
STS-1 #3 (TUG3 #3). When TUGEN is low, VTPP #3, RTOP #3 and RTTB #3
are held in a low power, reset state. The data in STS-1 #3 (TUG3 #3) is re-
transmitted unchanged on the outgoing data stream. The amount of delay
from the incoming to the outgoing data stream is a function of the internal
data-path pipeline delay and GSCLK_FP input. See the bypass functional
timing diagram for details. When TUGEN is set low, all VTTP #3, RTOP #3,
and RTTB #3 registers are reset to their default states.
Before the TUGEN bit is set high, it is essential to first set the
NOIC1J1PLBYP bit in the STP VTPP #3 Configuration #2 register high. This
will ensure that the re-transmission of the corresponding input Telecom Bus
signals, IC1J1 and IPL, to the output Telecom Bus is terminated gracefully.