PM5362-RI 参数 Datasheet PDF下载

PM5362-RI图片预览
型号: PM5362-RI
PDF下载: 下载PDF文件 查看货源
内容描述: SONET / SDH支路单元荷载处理器/性能监控 [SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR]
分类和应用: 监控监视器
文件页数/大小: 354 页 / 1028 K
品牌: PMC [ PMC-SIERRA, INC ]
 浏览型号PM5362-RI的Datasheet PDF文件第49页浏览型号PM5362-RI的Datasheet PDF文件第50页浏览型号PM5362-RI的Datasheet PDF文件第51页浏览型号PM5362-RI的Datasheet PDF文件第52页浏览型号PM5362-RI的Datasheet PDF文件第54页浏览型号PM5362-RI的Datasheet PDF文件第55页浏览型号PM5362-RI的Datasheet PDF文件第56页浏览型号PM5362-RI的Datasheet PDF文件第57页  
PM5362TUPP-PLUS  
DATA SHEET  
PMC-951010  
ISSUE 6  
SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR  
Pin Name Type  
Pin  
No.  
Function  
POHFP[3] Output 67  
The tributary path overhead frame pulse signals  
(POHFP[3:1]) may be used to locate the  
individual path overhead bits of each tributary  
for the corresponding STS-1 (TUG3) stream.  
Each POHFP signal is set high to mark bit 1 (the  
most significant bit) of the V5 byte of the first  
tributary. POHFP[3], POHFP[2] and POHFP[1]  
identify frame boundaries of the tributary path  
overhead bytes from STS-1 #1, #2 and #3,  
respectively. In AU4 mode, POHFP[3],  
POHFP[2]  
POHFP[1]  
107  
133  
POHFP[2] and POHFP[1] identify frame  
boundaries of TUG3 #1, #2 and #3, respectively.  
Each POHFP signal is updated on the falling  
edge of POHCK.  
POHEN[3] Output 77  
The tributary path overhead enable signals  
(POHEN[3:1]) may be used to identify tributary  
path overhead bytes that are being presented  
on the corresponding POH stream for the first  
time. Each POHEN signal is set high when a  
fresh overhead byte is available on the  
POHEN[2]  
POHEN[1]  
111  
139  
corresponding POH stream. POHEN is set low  
when the tributary path overhead byte available  
on the corresponding POH stream has already  
been shifted out in a previous frame.  
POHEN[3], POHEN[2] and POHEN[1] identify  
the status of tributary path overhead bytes from  
STS-1 #1, #2 and #3, respectively. In AU4  
mode, POHFP[3], POHFP[2] and POHFP[1]  
identify the status of tributary path overhead  
bytes from TUG3 #1, #2 and #3, respectively.  
Each POHEN signal is updated on the falling  
edge of POHCK.  
RAD  
Output 124  
The receive alarm port (RAD) contains the  
tributary path BIP error count, the RDI status  
and the PDI status of each tributary in the  
ID[7:0] bus. RAD is updated on the falling edge  
of POHCK.  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  
33  