SONET/SDH TRIBUTARY UNIT PAYLOAD PROCESSOR / PERFORMANCE MONITOR  
Register 0EH: RTOP #3 and RTTB #3 Configuration  
Bit  
Type  
Function  
Default  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
R/W  
R/W  
ALGO2  
PER5  
0
0
X
X
0
1
1
0
Unused  
Unused  
RDI10  
PDI[2]  
PDI[1]  
PDI[0]  
R/W  
R/W  
R/W  
R/W  
This register configures the operation of RTOP #3 and RTTB #3.  
PDI[2:0]:  
The PDI[2:0] bits specifies the code used to convey tributary path defect  
indication (PDI-V) in the V5 byte (for non-TU3 payloads) or the C2 byte (for  
TU3 payloads). For TU3 payloads, the PDI[2] bit is sign extended to form the  
byte value used for the PDI-V detection.  
RDI10:  
The RDI10 bit controls the number of times the tributary path RDI, RFI or the  
extended RDI code is filtered before being accepted. When RDI10 is set  
high, the RDI bit, the RFI bit or the extended RDI code is filtered for ten  
occurrences. When RDI10 is set low, the RDI bit, the RFI bit or the extended  
RDI code is filtered for five occurrences.  
PER5:  
The PER5 bit controls the number of identical tributary path trace messages  
needed for the message to become accepted. When PER5 is set high, a  
messages is accepted when it is received unchanged five times. When PER5  
is set low, the message is accepted after three identical repetitions.  
ALGO2:  
The ALGO2 bit controls the algorithm used to detect trail trace identifier  
unstable alarms. When ALGO2 is set high, a counter starts on the first  
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE  