PMC-Sierra, Inc.
PM5356
S/UNI-622-MAX
DATASHEET
S/UNI-622-MAX
PMC-1980589
ISSUE 5
SATURN USER NETWORK INTERFACE (622-MAX)
BIPEE:
The BIPEE bit is an interrupt enable for the line BIP-96 errors. When BIPEE is set to logic
one, an interrupt is generated when a line BIP-96 error (B2) is detected.
FEBEE:
The FEBEE bit is an interrupt enable for the line far end block errors. When FEBEE is set to
logic one, an interrupt is generated when FEBE (Z2) is detected.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
103