PMC-Sierra, Inc.
PM5356
S/UNI-622-MAX
DATASHEET
S/UNI-622-MAX
PMC-1980589
ISSUE 5
SATURN USER NETWORK INTERFACE (622-MAX)
Register 0x12: RSOP Section BIP-8 LSB
Bit
Bit 7
Type
Function
Default
R
R
R
R
R
R
R
R
SBE[7]
SBE[6]
SBE[5]
SBE[4]
SBE[3]
SBE[2]
SBE[1]
SBE[0]
X
X
X
X
X
X
X
X
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Register 0x13: RSOP Section BIP-8 MSB
Bit
Bit 7
Type
Function
Default
R
R
R
R
R
R
R
R
SBE[15]
SBE[14]
SBE[13]
SBE[12]
SBE[11]
SBE[10]
SBE[9]
X
X
X
X
X
X
X
X
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
SBE[8]
SBE[15:0]:
Bits SBE[15:0] represent the number of section BIP-8 errors (individual or block) that have
been detected since the last time the error count was polled. The error count is polled by
writing to either of the RSOP Section BIP-8 Register addresses. Such a write transfers the
internally accumulated error count to the Section BIP-8 registers within approximately 7 µs
and simultaneously resets the internal counter to begin a new cycle of error accumulation.
This transfer and reset is carried out in a manner that ensures that coincident events are not
lost.
The count can also be polled by writing to the S/UNI-622-MAX Master Reset and Identity
register (0x00). Writing to register address 0x00 loads all the counter registers in the RSOP,
RLOP, RPOP, RXCP and TXCP blocks.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
97