PM4341AT1XC
DATA SHEET
PMC-900602
ISSUE 7
T1 FRAMER/TRANSCEIVER
DTRKC:
When the DTRKC bit is set to a logic 1, data from the Data Trunk
Conditioning Code Byte replaces the BRPCM output data for the duration of
that channel.
DMW:
When the DMW bit is set to a logic 1, the digital milliwatt pattern replaces the
BRPCM output data for the duration of that channel.
Data inversion, data trunk conditioning, and digital milliwatt insertion are
performed independent of the received framing format. Digital milliwatt insertion
takes precedence over data trunk conditioning which, in turn, takes precedence
over the various data inversions.
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
180